missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ eBioscience™ Intracellular Fixation & Permeabilization Buffer Set

Designed for use in intracellular staining and flow cytometric analysis and has been specially formulated to reduce non-specific staining of fluorochrome-labelled antibodies and increase fluorescence signal-to-noise ratios.

Brand:  Invitrogen™ 88-8824-00


Product Code. 15284728

  • 193.00 € / Each
In Stock
to see stock.
Edge
Explore more special offers
Add to basket

Alert:

Contains Sodium azide and formaldehyde


Includes:
  • IC Fixation Buffer
  • Permeabilization Buffer (10X)
This item is not returnable. View return policy

Description

Description

  • In the first step, live cells can be 'fixed' with the Fixation Buffer, which cross- links proteins
  • The second step, using the Permeabilization Buffer, creates holes in the membrane and allows the intracellular staining antibodies to enter the cell effectively
  • Subsequent washing steps, antibody additions, and incubations after cell permeabilization should be performed using the Permeabilization Buffer
  • Final washing step and cell resuspension prior to running the sample is done using Flow Cytometry Staining Buffer (cat. 00-4222).
  • This kit is commonly used to stain cytoplasmic proteins and proteins in the secretory pathway such as chemokines and cytokines
  • Not recommended for intranuclear staining. Instead, please refer to the Foxp3/Transcription Factor Buffer Set for nuclear staining
  • Before the fixation step, it is recommended to label the live cells using one of the Fixable Viability Dyes and then proceed with fixation
  • TRUSTED_SUSTAINABILITY
Specifications

Specifications

eBioscience™
Fixation/Permeabilization Buffer Set
1 kit
Fixation/Permeabilization Buffer
Product Suggestions

Product Suggestions

Videos
Safety and Handling

Safety and Handling

Product Identifier
  • eBioscience Intracellular Fixation & Permeabilization Buffer Set

Signal Word
  • Danger

Hazard Category
  • Carcinogenicity Category 1A
  • Serious eye damage/eye irritation Category 1
  • Germ cell mutagenicity Category 2
  • Skin sensitiser Category 1
  • Specific target organ toxicity Category 2

Hazard Statement
  • H317-May cause an allergic skin reaction.
  • H318-Causes serious eye damage.
  • H341-Suspected of causing genetic defects.
  • H350-May cause cancer.
  • H371-May cause damage to organs.

Precautionary Statement
  • P201-Obtain special instructions before use.
  • P261-Avoid breathing dust/fume/gas/mist/vapours/spray.
  • P264-Wash hands thoroughly after handling.
  • P270-Do not eat, drink or smoke when using this product.
  • P280-Wear protective gloves/protective clothing/eye protection/face protection.
  • P302+P352-IF ON SKIN: Wash with plenty of water/soap.
  • P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P308+P313-IF exposed or concerned: Get medical advice/attention.
  • P310-Immediately call a POISON CENTER/doctor/.
  • P332+P313-If skin irritation occurs: Get medical advice/attention.
  • P501b-Dispose of contents/container in accordance with local/regional/national/international regulations.

Supplemental information
  • MIXTURE LIST-Contains : Paraformaldehyde

SDS
Documents

Documents

Certificates
Promotions

Promotions

Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Thank You! Your feedback has been submitted. Fisher Scientific is always working to improve our content for you. We appreciate your feedback.

For Research Use Only. Not for use in diagnostic procedures.