Sartorius Sterisart™ NF Sterility Testing System
BIOPHARMA

Product Code. 15972530 Shop All Sartorius Products
Click to view available options
Sterilization Method:
EtO
Gamma Irradiation
Sample Composition:
Easily Dissolved Powders
Liquids
Includes:
Female luer lock connector
Long dual-needle spike, sterile vented
Long dual-needle spike, sterile vented, septum
Long needle, by-packed sterile venting needle
Long needle, side opening w/solid pointed tip
Long needle, sterile venting needle, septum
Luer (Lock) connection, by-packed long needle, sterile venting
Short dual-needle spike, sterile vented
Short dual-needle spike, sterile vented, with septum
Tubing system w/ two dual-needle metal spikes of different length
Two dual-needle spikes of different length, one sterile vented w/septum
Two dual-needle spikes of different length, sterile vented
Universal Luer adapter, long dual-needle spike, sterile vented
Universal Luer adapter, long dual-needle spike, sterile vented, septum
Sampling Option:
No Septum
Septum
Tamaño de la unidad:
Pack of 10
Este artículo no se puede devolver. Vea la política de devoluciones

Código de producto. 15972530

Marca: Sartorius 16476GSD

Solo quedan null
Añadir a la cesta
Añadir a la cesta
Este artículo no se puede devolver. Vea la política de devoluciones

Provides completely closed system sterility testing of pharmaceuticals, open containers, closed containers, pre-filled syringes, powders, and medical devices. Sartorius Sterisart™ NF Sterility Testing System is optimal for use with isolators.

International pharmacopoeias require the complete sterility of pharmaceutical products that are injected into the blood stream or that otherwise enter the body below the skin surface. As a manufacturer of such products, you are required to supply proof of sterility of the final product batch. Sterisart™ NF is a completely closed system for the sterility testing of pharmaceutical products. It is based on the membrane filter method, however it eliminates the procedure of manipulating the filters. By this the main risk of a secondary contamination and false positive results is eliminated. A peristaltic pump transfers the sample into the filtration units, and after rinsing, the filtration units are filled with media and used for incubation of the filters without any contact to the environment.

  • reliable Sartochem™ membrane
  • high retention of microbes
  • low adsorption
  • high mechanical stability
  • pre-installed color-coded tube clamps
  • easy-to-read graduated marks
  • user-friendly (several practical adapters available)
  • product-/lot number identification
  • gas-impermeable packaging for protection against sterilants
TRUSTED_SUSTAINABILITY

Especificaciones

Capacity (English) 4 oz.
Capacity (Metric) 120 mL
For Use With (Application) Sterility Testing
For Use With (Equipment) Closed Glass Vials with Septum
Model Sterisart Consumable
Temperature (English) 122°F
Temperature (Metric) 50°C
Filtration Area 15.7 cm
Includes Short dual-needle spike, sterile vented, with septum
Pore Size 0.45 μm
Operating Pressure 3 bar at 20°C
Sample Type SVPs
Sample Composition Liquids
Sampling Option Septum
Sterilization Method Gamma Irradiation
Sterility Sterile
Mostrar más Mostrar menos
Corrección del contenido de un producto

Proporcione sus comentarios sobre el contenido del producto rellenando el siguiente formulario.

Título del producto

Al hacer clic en Enviar, acepta que Fisher Scientific se ponga en contacto con usted en relación con los comentarios que ha proporcionado en este formulario. No compartiremos su información para ningún otro fin. Toda la información de contacto proporcionada se mantendrá de acuerdo con nuestra Política de Privacidad. Política de privacidad.

Gracias por ayudarnos a mejorar nuestra web. Su comentario ha sido enviado