missing translation for 'onlineSavingsMsg'
Learn More
Learn More
Cytiva Whatman™ Non-sterile ME 25 Mixed Cellulose Ester Membranes
Offers a larger adsorption of product with a high degree of internal surface area. Whatman™ Non-sterile ME25 Mixed Cellulose Membranes are available plain for automatic colony counting applications, as well as gridded to assist in manual counting procedures.
Brand: Cytiva 10406812
Questo articolo non è restituibile.
Consulta la politica di reso
Descrizione
Offers a larger adsorption of product with a high degree of internal surface area. Whatman™ Non-sterile ME25 Mixed Cellulose Membranes are available plain for automatic colony counting applications, as well as gridded to assist in manual counting procedures.
Composed of cellulose acetate and cellulose nitrate characterized by a smooth and uniform surface. Color contrast provided by the filter surface facilitates particle detection and minimizes eye fatigue.- Gridded surface (3.1mm intervals) make filters ideal for colony counting after incubation
- Special nontoxic ink used is completely free from bacterial growth inhibitors
- Manufactured under strictly controlled cleanroom conditions
- Pore size: 0.45μm
Specifica
Autoclavable | |
Mixed Cellulose Ester | |
0.45 μm | |
Black | |
Interleaving paper | |
3.1mm | |
266°F | |
145 μm | |
12.5 sec./100mL/12.5cm2 | |
47 mm |
White | |
ME 25 | |
Non-sterile | |
Hydrophilic | |
Medium | |
Grid | |
130°C | |
Membrane | |
1.85 in. |
Sicurezza e movimentazione
Identificativo prodotto
Avvertenza
Categoria di pericolo
Indicazioni di pericolo
Consigli di prudenza
Informazioni supplementari
- ME25/21, 0.45µm 47mm
Avvertenza
- Warning
Categoria di pericolo
- Flammable solid Category 2
Indicazioni di pericolo
- H228-Flammable solid.
Consigli di prudenza
- P280-Wear protective gloves/protective clothing/eye protection/face protection.
- P210-Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Informazioni supplementari
- MIXTURE LIST-Contains : nitrocellulose