Filtered Search Results
Search results for "astm"
Fisherbrand™ Soil Analysis ASTM Hydrometers
These hydrometers are used to determine the specific gravity of soil in the range of 0.995 to 1.038 or -5 to 60g/L (using a weight by volume scale).
Content And Storage | Soil analysis hydrometers should be stored in a clean, dry, safe place, and should not be subjected to extreme temperatures. |
---|---|
Length (Metric) | 280 mm |
Certifications/Compliance | Traceable to NIST |
For Use With (Application) | To determine the specific gravity of soil in the range of 0.995 to 1.038 or -5 to 60g/L (using a weight by volume scale) |
Bel-Art™ H-B Durac Soil Analysis ASTM Hydrometer
Used to determine the specific gravity of soil, these hydrometers conform to the accuracy requirements of ASTM hydrometers.
SI Analytics™ Ubbelohde ASTM Viscometer
Determine absolute and relative kinematic viscosity of liquids with Newtonian flow behavior. SI Analytics™ Ubbelohde ASTM Viscometer includes ring marks to ensure that they can be checked by means of manual measurements.
ASTM Numbers | D 446 |
---|---|
Product Type | Viscometer |
Certifications/Compliance | ISO/DIS 3105, ASTM D 2515, ASTM D 446 |
For Use With (Application) | Manual Measurements and Automatic Measurements |
Calibrated | Yes |
SI Analytics™ Ubbelohde Viscometers, ASTM
Determine absolute and relative kinematic viscosity of liquids with Newtonian flow behavior. SI Analytics™ Ubbelohde Viscometers, ASTM includes ring marks to ensure that they can be checked by means of manual measurements.
Length (Metric) | ∼285 mm |
---|---|
Product Type | Ubbelohde ASTM Viscometer |
Volume (Metric) | 15 to 20 mL |
Certifications/Compliance | ISO 3105, ASTM D 2515, ASTM D 446 |
For Use With (Application) | Determining the viscosity of Newtonian liquids |
Calibrated | Yes |
SI Analytics™ Ubbelohde Viscometer (ASTM)
Ubbelohde viscometers are calibrated for automatic measurements
SI Analytics™ Ubbelohde Viscometers (ASTM)
SI Analytics™ Ubbelohde Viscometers (ASTM) feature a suspended ball level for determination of absolute and relative kinematic viscosity of liquids with Newtonian flow behavior.
Fisherbrand™ ASTM™ Specific Gravity Hydrometers for Liquids Lighter than Water
Accuracy of hydrometer meets or exceeds ASTM™ E 100 specifications.
TempofStandardization | 60°F |
---|
Fisherbrand™ ASTM™ Specific Gravity 275mL Hydrometers for Liquids Heavier than Water
Accuracy meets or exceeds ASTM E 100 specifications.
TempofStandardization | 60°F |
---|---|
Length (Metric) | 330 mm |
Volume (Metric) | 275 mL |
Increments | 0.0005 |
For Use With (Application) | Liquids heavier than Water |
Fisherbrand™ ASTM™ Specific Gravity 260mL Hydrometers for Liquids Heavier than Water
Accuracy meets or exceeds ASTM E 100 specifications.
TempofStandardization | 60°F |
---|---|
Length (Metric) | 260 mm |
Volume (Metric) | 260 mL |
Increments | 0.001 |
For Use With (Application) | Liquids heavier than Water |
Sartorius arium™ Pro ASTM TYPE 1 - Ultrapure Water System, Benchtop
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Produce ASTM type 1 water for critical analysis like HPLC, PCR, antibody production, cell culture media preparation or electrophoresis by adding a arium™ Pro ASTM TYPE 1 - Ultrapure Water System to your lab.
Height (Metric) | 49.2 cm |
---|---|
Electrical Requirements | 100/240 V 50/60 Hz |
Depth (English) | 17.75 in. |
Width (English) | 13.7 in. |
pH Range | 4 to 10 |
Feedwater Temperature (English) | 35.6°F to 86°F |
Storage Requirements | 5°C to 45°C |
Humidity Range | 80% |
Width (Metric) | 35 cm |
Particle Size | <1/mL |
Mounting | Benchtop |
Purification Method | Adsorption by spherical activated Carbon, deionization, optional final particle and sterile filtration |
Depth (Metric) | 45.1 cm |
Product Water Type | Type 1 |
Voltage | 100/240 V |
Turbidity | <1 |
Frequency | 50/60 Hz |
Temperature Range (English) | 35.6°F to 95°F |
Weight (English) | 59.5 to 63.9 lb. |
Feedwater Temperature (Metric) | 2°C to 30°C |
Certifications/Compliance | ASTM |
Temperature Range (Metric) | 2°C to 35°C |
Bacterial Content | <1 CFU/L |
Weight (Metric) | 27 to 29 kg |
Height (English) | 19.37 in. |
H-B Instrument™ Durac™ Specific Gravity ASTM Hydrometers: for Heavy Liquids
Available in a variety of models measuring specific gravity of heavy and light liquids in various ranges from 0.650 to 2.000
Content And Storage | ASTM hydrometers should be stored in a clean, dry, safe place. They should not be subjected to extreme temperatures. |
---|---|
Certifications/Compliance | Packaged with a multi-language (English, French, German, Italian, Portuguese, and Spanish) Statement of Accuracy indicating accuracy traceable to NIST. Hand inspected by U.S. quality team in exclusive triple accredited/registered ISO/IEC 17025:2005 and A2LA Accredited Calibration Laboratory; internationally recognized and accepted by the signatory economies of the ILAC/MRA and located in ISO 14001:2004 Environmental Management System registered facility. Conforms to American Society of Testing Materials (ASTM) E100 standards. |
For Use With (Application) | For Heavy Liquids |
Sartorius arium™ comfort II ASTM 1, 2 Combined Water purification Systems with UV Lamp
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Use the Sartorius arium™ comfort I Combined System for producing ASTM Type 1 ultrapure water and Type 2 pure water.
Feedwater Pressure | 2.0 to 6.9 bar |
---|---|
Height (Metric) | 50.1 cm |
Electrical Requirements | 100/240 VAC (+/-10%) 50/60 Hz 130 VA (max.) |
Depth (English) | 18.7 in. |
Width (English) | 17 in. |
Daily Output | 120 L/hr. (Type 1), 5 L/hr. or 10 L/hr. (Type 2) |
Humidity Range | 80% |
For Use With (Application) | HPLC, GC-MS, AAS, ICP-MS, Ion chromatography, TOC Analysis, Photometry, Microbiological media and reagents, Histology, ELISA, RIA |
Width (Metric) | 43.5 cm |
Particle Size | <1mL |
Includes | UV lamp |
Purification Method | Adsorption using spherical activated carbon, catalyst, reverse osmosis, electrochemical deionization, optional final particle and sterile filtration |
Type | Water Purification System |
Depth (Metric) | 47.6 cm |
Product Water Type | Type 1 and 2 |
Turbidity | <1 NTU |
Weight (English) | 61.7 lb. (Empty); 79.3 lb. (Operating) |
Feedwater Temperature (Metric) | 2°C to 30°C |
Bacterial Content | <1 CFU/L |
Weight (Metric) | 28 kg (Empty); 36 kg (Operating) |
Height (English) | 19.7 in. |
Sartorius arium™ advance EDI Electodeionization Water System, ASTM Type 2
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Outfit your lab with he Sartorisu™ arium™ advance EDI provide consistently high quality Type 2 water.
Contaminant Rejection (Organic) | Greater than99% |
---|---|
Width (English) | 13.7 in. |
pH Range | 4 to 10 |
Feedwater Temperature (English) | 35.6°F to 86°F |
Contaminant Rejection (Microbiological) | Greater than99% |
Humidity Range | 80% |
For Use With (Application) | Feed water for laboratory devices, such as autoclaves, Glassware washers, humidifiers, water baths etc |
Width (Metric) | 35 cm |
Total Organic Carbon | <50 product water, <1000 feed water |
Product Water Type | Type 2 |
Voltage | 100/240 V |
Turbidity | <1 |
Feedwater Temperature (Metric) | 2°C to 30°C |
Weight (Metric) | 26 kg |
Height (English) | 19.7 in. |
Height (Metric) | 50.1 cm |
Electrical Requirements | 100/240 V 50/60 Hz |
Depth (English) | 17.75 in. |
Resistivity | <5 to 15 product water |
Tolerance | 4 |
Conductivity | 0.2 to 0.07 Product water, Less than1500 feed water |
Daily Output | <10 |
Storage Requirements | 5°C to 45°C |
Particle Size | <1/mL |
Depth (Metric) | 45.1 cm |
Frequency | 50/60 Hz |
Temperature Range (English) | 35.6°F to 95°F |
Weight (English) | 57.3 lb. |
Temperature Range (Metric) | 2°C to 35°C |
Bacterial Content | <1 CFU/L |