missing translation for 'onlineSavingsMsg'
Läs mer

Fisherbrand™ accumet™ Glass Body Ag/AgCl Reference Electrodes - Mercury-Free

Produktkod. 11530094 Handla allt< titel> Produkter
missing translation for 'orderingAttributeHoverText'
Reference Electrolyte:
13-620-833
SP138-500
SP138-500, SP135-500
Förpackningsstorlek
Each
Denna artikel kan inte returneras. Se returpolicy

Produktkod. 11530094

Bara null kvar
Lägg i varukorgen
Lägg i varukorgen
Denna artikel kan inte returneras. Se returpolicy

Recommended for stability at higher temperatures and for use with strongly basic samples

Glass body for resistance to wide variety of solutions

  • Operating temperature range of 0° to +110°C (32° to 212°F)
  • 0 to 14pH range
  • Standard reference pin connector
  • All have 8μL/hr. flowrate

 

Single-Junction Standard Model

  • Standard size glass body
  • Prefilled with 4M KCl saturated with AgCl
  • Stable at higher temperatures and with strongly basic samples
Single-Junction Side Arm Model
  • Standard size glass body with 1 in. (25mm) tubulation fitting, handy for procedures that require remote filling
  • Prefilled with 4M KCl saturated with AgCl
  • Stable at higher temperatures and with strongly basic samples
Single-Junction Silver/Chloride Titration Model
  • Standard size glass body
  • Prefilled with 1M sodium sulfate for silver and chloride titrations
  • Stable at higher temperatures and with strongly basic samples
Double-Junction Model
  • Designed for ISE and sensitive pH measurements, titrations and ORP testing
  • Inner body is prefilled with 4M KCl saturated with AgCl
  • Outer body is packed without electrolyte, so you can choose a compatible electrolyte for your samples
  • Flowrate, 8μL/hr.
  • U.S. Patent No. 4,390,406

 

TRUSTED_SUSTAINABILITY

Specifikationer

Connector Types Pin
Junction Single
Material Glass
pH Range 0 to 14
Temperature (Metric) Operating 0°C to 100°C
Type Ag/AgCl Reference Electrode
Electrode Suggested Indicating Electrodes: 13-620-122
Filling Solution Type 4mol/L KCl with AgCl
For Use With (Application) Recommended for stability at higher temperatures and for use with strongly basic samples
Internal Reference Ag/AgCl
Model Single-Junction High Temperature Ag/AgCl Reference for Silver and Chloride Titrations
Reference Electrolyte 13-620-833
Temperature (English) Operating 32°F to 212°F
Temperature (Metric) Range 0°C to 100°C
Length (Metric) 106 mm
Diameter (Metric) Body 12 mm
Visa mer Visa mindre
Korrigering av produktinnehåll

Din input är viktig för oss. Fyll i det här formuläret för att ge feedback relaterad till innehållet på denna produkt.

Produkttitel

Genom att klicka på Skicka bekräftar du att du kan bli kontaktad av Fisher Scientific angående feedbacken du har lämnat i detta formulär. Vi kommer inte att dela din information för andra ändamål. All kontaktinformation som tillhandahålls ska också underhållas i enlighet med vår Sekretesspolicy.

Tack! Din feedback har skickats. Fisher Scientific arbetar alltid för att förbättra vårt innehåll åt dig. Vi uppskattar din feedback.