Inline Electrochemistry Analyzers

Inline Electrochemistry Analyzers
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)

IKA™ ElectraSyn 2.0 Package
Combination potentiostat, analytical device, and stir plate with vial, holder, and electrodes.
Thermo Scientific™ Orion™ 2230XP Silica Analyzer Reagents and Standards
The reagents and calibration standards you need to operate and maintain the Thermo Scientific™ Orion™ 2230XP Silica Analyzer.
Thermo Scientific™ Orion™ 2120XP Calcium Hardness Analyzer Accessories and Kits
Accessories and kits for the Thermo Scientific™ Orion™ 2120XP Calcium Hardness Analyzer include a consumables kit, calibration kit, carrying case, electrode kit and faceplate.
For Use With (Equipment) | Orion™ 2120XP Calcium Hardness Analyzer |
---|---|
Temperature (Metric) Operating | 5°C to 45°C (Ambient) |
Thermo Scientific™ AquaPro™ Multi-Input Intelligent Process Transmitters
Streamline process monitoring with the Thermo Scientific™ AquaPro™ Multi-Input Intelligent Transmitter. The AquaPro provides accurate, user-friendly monitoring in-line via a reliable, simplified interface, and can be upgraded in the field to accept up to four inputs.
Max. Relative Humidity | 95%, non-condensing |
---|
Thermo Scientific™ Orion™ 2117XP Chloride Analyzer
Detect chloride in real time with accurate and reliable results using the Thermo Scientific™ Orion™ 2117XP Chloride Analyzer.
Enclosure Rating | Waterproof; IP66; NEMA 4X |
---|---|
Width (English) | 17 in. |
Length (Metric) | 27 cm |
Response Time | 95% within 2 minutes of injecting a standard solution |
Detection Limits | 0.1ppm |
Length (English) | 11 in. |
Width (Metric) | 45 cm |
Channels | 1 |
Channel1 | Chloride |
Sample Streams | 1 |
Channel2 | Optional ph/ORP or Conductivity |
Flow Rate | 40mL/min. |
Accuracy | ±10% or 0.1 ppm, whichever is greater |
Mounting Options | Wall mount |
Display Type | Custom backlit LCD with temperature, concentration, mV, error codes and menu driven prompts |
Voltage | 85 to 132 VAC; 170 to 264 VAC |
Amperage | 5A |
Inlet Pressure | 8 to 100psig |
Certifications/Compliance | CE, CSA, UL, FCC Class A limits |
Analog Outputs | 2, Galvanically Isolated |
Case Material | Valox 364 |
Accuracy (Temperature) | ±0.5°C |
Relay Details | 3 Relay Outputs; Relay Load: 250VAC; 30VDC; 5A |
Height (English) | 26 in. |
Height (Metric) | 65 cm |
Communication Details | Modbus with Additional Module |
Accuracy (mV) | ± (0.5 mV + 0.1%) |
Keypad Type | Membrane |
Measurement Ranges | 0 to 10ppm |
Calibration | Double Known Addition |
Sample Flow Rate | 40 mL/min nominal set by pressure regulator |
Current Loops | 2 |
Alarm Output | 3 |
Type | Chloride Analyzer |
Dimensions (L x W x H) | 11 x 17 x 26 in. (27 x 45 x 65cm) |
Max. Relative Humidity | 5 to 95%, non-condensing |
Outputs | 0 to 20 mA; 4 to 20 mA |
Frequency | 0 to 60 Hz |
Temperature (Metric) Operating | 5°C to 35°C |
Sample Inlet | 1/4 in. NPTF tube fitting |